Standard Certifications & Technical Support
Legal capacity dossiers, ISO 9001:2015 certifications, QUATEST 1 quality test reports, and electrical engineering guides.
1. Quality Certifications & Inspection Reports
Dan Chu Electric Equipment Joint Stock Company always places product quality and operational safety first. All equipment is manufactured in strict compliance with national and international standards:
Construction Activity Capacity Certificate
- Certificate No: HAN-00073840
- Issued by: Hanoi Dept. of Construction (Dec. 188/QD-SXD)
- Validity: Until June 19, 2033 (10 years)
- Scope: Power lines & substations, industrial buildings, energy projects.
ISO 9001:2015 QMS Certification
- Certificate No: 260193.QMS.CN26 (VICAS 022-QMS)
- Certifying Body: ICB International Certification JSC
- Validity: 09/03/2026 - 08/03/2029 (3-year cycle)
- Scope: Manufacture & installation of switchboards, substations, kiosk stations.
ISO 9001 Certification Decision
- Decision No: 260193.QMS.CN26/QĐCN-ICB
- Issued Date: 09/03/2026 signed & sealed by ICB Director
- Accreditation Body: Bureau of Accreditation (BoA)
- Compliance: Full compliance with management system audit standards.
QUATEST 1 Type Test Report
- Report No: 20/0042/TN2-01 (Issued by QUATEST 1)
- Testing Center: Quality Assurance & Testing Center 1 (QUATEST 1)
- Test Sample: LV Switchboard 600V - 300A & 400A (Complete assembly)
- Standards: IEC 60439-1, IEC 60947-2, IEC 60529 (IP54).
Business Registration (Legal)
- Enterprise Code: 0105761509
- Issued by: Hanoi Department of Planning & Investment
- Registration Date: 05/01/2012 (5th Amendment: 28/11/2024)
- Representative: Director Nguyen Thi Hoang Then
Field Grid Operation Confirmation
- Confirmed by: Kim Thanh Power & Chi Linh Power
- Scope: Single-pillar substations with RMU, LV panels, and capacitor banks
- Service Area: Hai Duong & neighboring active power grids
- Evaluation: Safe power supply and absolute operational reliability.
2. Technical Specifications of Core Product Lines
Medium Voltage Metal-Clad Switchgear (MCSG)
Rated Voltage:
3.3 / 7.2 / 12 / 24 / 36 / 40.5 kV
Rated Current:
200A to 3150A
Short-Circuit Current:
12.5 / 16 / 25 / 31.5 / 40 kA
Standard:
IEC 62271-200
Ring Main Unit (RMU) Medium Voltage Switchgear
Rated Voltage:
12 / 24 / 36 / 40.5 kV
Rated Current:
200 / 630 / 1250 A
Short-Circuit Current:
16 / 20 / 25 kA
Standard:
IEC 298 / IEC 62271-200
Compact Kiosk Transformer Substation
Voltage Level:
6 / 10 / 22 / 35 kV
Transformer Capacity:
31.5 kVA to 3000 kVA
Structure:
3 independent compartments
Standard:
IEC 60265, IEC 60298, IEC 60529
Low Voltage Distribution Switchboard (MSB / MDB / DB)
Operating Voltage:
220V to 690V
Rated Current:
Up to 6300A
Breaking Capacity:
Up to 150 kA
Protection Degree:
IP30 to IP65 (IEC 60529)
3. Switchboard Form Separation & Fire Safety Standards
Form 2B - 3B
Separates busbars from functional switching units, suitable for commercial buildings and standard industrial workshops.
Form 4A & 4B (Dân Chủ Electric)
Highest safety level: Complete independent compartmentalization between busbars, each functional unit, and individual cable termination compartments.